Backflow Preventer Repair and Protection in Tyler, TX
We service all sprinkler brands β including Rain Bird, Hunter, Orbit, Rachio, Toro, Irritrol, and K-Rain. Hunter is the brand we love and recommend.
The backflow preventer sits between your drinking-water supply and the sprinkler system. Its job is to keep irrigation water from moving backward into the house supply. When it leaks, freezes, or will not hold, the sprinklers may be unusable, and the yard near the assembly can stay wet. East Texas Sprinkler Repair diagnoses, installs, repairs, and replaces irrigation backflow preventers, and we winterize aboveground units. Owner Bill Harthcock is a Texas licensed irrigator, licensed since 1987 (LI 0003482). Call or text (903) 730-6471, 24/7, or book online.
Texas requires a backflow preventer on an irrigation system connected to potable water. We work on the common types we see in East Texas, including underground double-check assemblies and aboveground pressure vacuum breakers (PVB) and reduced-pressure zone assemblies (RPZ).
Signs the backflow preventer needs work
You may notice a problem at the assembly itself, or only after a zone runs:
Water weeps or sprays from the assembly, a union, a test cock, or a relief opening.
The area around the backflow preventer is soft, stained, or growing algae.
The body, a fitting, or a ball valve is cracked, often after a freeze.
A zone or the whole system has lost pressure, and the leak appears to start at the point of connection rather than in the yard.
The assembly was recently hit by a mower, string trimmer, or vehicle.
You can hear water moving at the assembly when the controller is off.
A wet spot at the assembly is not always the backflow preventer. A leaking isolation valve, a fitting just downstream, or a nearby sprinkler leak can look the same until someone isolates it.
How we repair and protect it
On a city-water system, we shut the dedicated irrigation isolation valve when we can, relieve pressure, and inspect the body, unions, ball valves, test cocks, and nearby pipe. If a part can be repaired or replaced without replacing the entire assembly, we will tell you. If the body is cracked, or the assembly is damaged beyond a sensible repair, we talk through replacement and matching the type already installed, unless a different layout is clearly needed. We also install a new backflow preventer when a system needs one.
Freeze damage is a frequent reason for this call in Tyler. Aboveground PVB and RPZ assemblies sit in the air and can split if they still hold water during a hard freeze. Underground double-check assemblies are generally at lower risk when they are adequately buried, though a shallow or wet valve box still deserves a look. After a repair, we can winterize the assembly. For an aboveground PVB or RPZ, that winterization is $149 plus the service charge and parts. For a typical underground city-water system, standard winterization is $75 plus the service charge and parts.
Winterization of an aboveground assembly is more than a cover. The supply is shut off, pressure is relieved, and trapped water is drained, with ball valves and test cocks left as the manufacturer specifies, often at about 45 degrees. A cover should not block required drainage or relief openings. If the unit is already cracked, see freeze damage repair.
We diagnose, install, repair, and replace irrigation backflow preventers. If your city or water utility requires a certified test, we can arrange certified backflow testing, performed by a certified backflow tester we work with (a subcontractor). Our own team does not hold the tester certification.
What affects the cost
Every backflow visit has a service charge plus any parts used. The service charge is $65 in Tyler and goes up about $10 for every additional 10 minutes of travel from Tyler. Parts may include a fitting, a ball valve, a cover, insulation, or a replacement assembly.
New customers get a FREE 10-point sprinkler system inspection, and the inspection itself has no service charge. Existing customers can get the same free inspection if they let us know before they book. Any repairs are separate and follow the usual service charge plus parts. See our services page for details.
The total depends on the type of assembly, whether we are repairing a leak, replacing a damaged body, or winterizing an intact unit, and whether nearby pipe also failed. Call or text (903) 730-6471 for the service charge at your address.
What you can do safely
If the assembly is leaking, shut the irrigation isolation valve, if you have one, and leave the sprinklers off until it can be looked at.
Before a hard freeze, shutting that valve is a useful first step, but it does not by itself drain an aboveground PVB or RPZ.
Do not disassemble the assembly or cap a relief opening to stop a drip. On an RPZ, that opening is part of how the device works.
If you use an insulated cover, do not block drainage or relief openings, and keep mowers and string trimmers away from the fittings.
If you cannot find the isolation valve, that can become part of a lost valve locating visit.
Backflow preventer FAQs
Do you service all sprinkler brands?
Yes. We service all brands, including Rain Bird, Hunter, Orbit, Rachio, Toro, Irritrol, and K-Rain. Hunter is the brand we love and recommend, but we will work on the system you already have. We are not a factory dealer and do not claim certified status with any manufacturer.
Is the 10-point inspection really free?
Yes. New customers get a FREE 10-point sprinkler system inspection, and the inspection itself has no service charge. Existing customers can get the same free inspection if they let us know before they book. If something needs repair, that work is separate and follows our usual service charge plus parts. The free inspection does not require you to approve any repairs.
What is the difference between a double-check, a PVB, and an RPZ?
In simple terms, a double-check is often installed underground and is generally less exposed to air temperatures. A PVB and an RPZ are typically aboveground. An RPZ has a relief opening and is used where a higher level of protection was specified. The right type is an installation and code question; we service the assembly you have and will tell you if something about it is damaged or incorrectly set up.
Can I just wrap it with a blanket in winter?
A wrap or a cover is not a complete winterization if the assembly is still full of water. Drainage matters more than insulation, especially in a freeze that lasts. If you want the unit protected, book winterization.
Why is my backflow preventer leaking only after it gets cold?
A hairline crack from a freeze may leak once the ice thaws and the system is charged again. It can also take a few temperature swings before a damaged body shows a visible spray. Shut the isolation valve and have it inspected.
Do you work on backflow preventers for lake pump systems?
Lake-pump irrigation is usually separate from the house potable supply, so the freeze-risk parts are often the pump and its piping rather than a city-water backflow preventer. See lake and pond pump systems. If your property has both city water and a pump, we can look at both.
Can you do the cityβs required backflow test?
Yes. We can arrange certified backflow testing, performed by a certified backflow tester we work with (a subcontractor). Our own team does not hold the tester certification. Diagnose, install, repair, and replace work is done by us.
Call, text, or book now
Call or text (903) 730-6471, 24/7. Book now.
Related services: leak detection, lost valve locating, controller repair, freeze damage repair, winterization, and lake and pond pumps. See all services.
East Texas Sprinkler Repair serves Tyler, Whitehouse, Lindale, Flint, Bullard, Chandler, Longview, and Kilgore. See all areas we serve.